Worldwide Support, Experienced Operators, Specialised Rental Solutions

6.2 MMbtu Zone II Steam Generator

Features
  • Single lift unit
  • Fully contained within one 20 x 8 container for reduced footprint and cost-effective transportation
  • Steam vents and safety valve vents mounted away from passing personnel
  • Internal intrinsically safe lighting enables safe operation and maintenance in all conditions
  • High and low water levels, high-pressure steam and flame failure shutdowns are fitted as standard as safety and protection measures
  • Gas Detection (propane, methane and H₂S)
  • Fitted with a Fire Suppression System
  • Airpac Rentals’s skilled operators ensure safe efficient operation of the equipment on site
  • Blowdown vessel for safe release of high pressure steam during working operations
  • The boiler includes forced air cooling to ensure surface temperatures below 200ºC are maintained

Options

Additional Steam Hose length available upon request

Airpac Rentals’s 6.2 MMbtu Zone II Steam Generators are installed in purpose built DNV 2.7-1 containers (fully compliant to DNV 2.7-2). 

The Steam Generators provide steam output of 6,200,000 Btu and have a working pressure of 10.3 bar (150 psi).

Each unit is delivered with internal water and fuel tanks, 200 feet of steam hose together with a comprehensive spares kit. These units have been engineered to be fully contained within one 20 x 8 container, ensuring a reduced footprint as well as cost-effective transportation.

When supplied as a package with our 1000 or 1600 cfm Zone II Air Compressors, they complete a fully compliant DNV 2.7-2 package. 

Airpac Rentals’s Steam Generators are ideal for hazardous area operations in offshore environments. The units are suitable for well testing operations or temporary replacement of installed boiler systems during maintenance. They are also suitable for use in industrial applications such as tank cleaning, descaling, shutdowns and heavy oil removal.

Airpac Rentals generators are designed to ASME/CE steam generator vessel codes.

An on board Emergency Shutdown System is fitted as standard ensuring instant safe shutdown should gas be detected. Each unit is also fitted with a Fire Suppression System.

Airpac Rentals also has an extensive rental fleet Rigsafe / Safe Area Steam Generators, producing volumes ranging from 1.4 Million Btu through to 6 Million Btu’s.

For the full technical specification of our Zone II steam generators, including weights and dimensions, please download the pdf datasheet.